Timing adjustment for Tower crates
Integral method

  • Procedure do integral of 60 towers at eta bin=5 (should have the same gain). Integral range [ped+10,ped+40]. Gain=100*sum/total. errGain=100*sqrt(sum)/total. 40-90K events used.

    CRATE 1 , best delay 15 ns, FIFO=19


    CRATE 2, best delay 0 ns, FIFO=19


    CRATE 3, best delay 85 ns, FIFO=19


    CRATE 4, best delay 80 ns, FIFO=19


    CRATE 5, best delay ?? ns, FIFO=19 , some towers did not responded


    CRATE 6, best delay 35 ns, FIFO=19