b STAR-SSD- Fiber measurements
logo star

STAR SSD

- Fiber measurements


Optical power at receiver boards

June 29:
RDO fiber # Patch panel measured power
1 W7 no -11.4 dBm
2 W4 no -3.4 dBm
3 E3 yes -2.3 dBm
3 E3 no -2.8 dBm
4 E2 yes -8.4 dBm

July 2: (note -- absolute scale has changed)
RDO fiber # Patch panel measured power
1 W7 no -12.5 dBm
2 W4 no -4.5 dBm
3 E3 yes -3.0 dBm
4 E2 no -10.2 dBm
4 E2 yes -10.6 dBm

Remarks:

Optical power at receiver boards

June 29:
RDO fiber # Patch panel measured power
1 W7 no -11.4 dBm
2 W4 no -3.4 dBm
3 E3 yes -2.3 dBm
3 E3 no -2.8 dBm
4 E2 yes -8.4 dBm

Measurements of fiber transmission using a light pulser at the RDO end of the fiber

July 6:
Note: measurement with light pulser connected to optical power meter by 1m of fiber
-2.8 dBm
Remember: the light source is different from that used in previous measurements.
Only the relative power for the following 4 measurements is important.
RDO fiber # Patch panel measured power
1 W7 no -9.4 dBm
2 W4 no -10.5 dBm
3 E3 yes -8.7 dBm
4 E2 yes -12.4 dBm

Conclusions

Measurements still to be performed




Last updated by mjl on