Description:
This is the procedure to turn on or off the Remote Threshold System for TOFr.
|
|
Related Documentation:
|
Requirements:
- Notification and Approval of TOFp Group.
- Access to STAR Subnet.
- Password Information (posted at TOF Station in STAR Control Room).
|
|
Procedure:
- Open the TOFr NPS Tutorial in a browser window
for reference.
- From any terminal window, make a telnet or ssh connection to
tofrnps.starp.bnl.gov (130.199.60.9). The password is posted at the
TOF Station in the Control Room.
- You are now logged into the TOFr Network Power Switch.
- Enter
/S
to display NPS Plug names and status.
- Locate in this listing the name "TOFr_Thresh".
Identify the plug number: 5
THRESHOLD SYSTEM ON
- Enter
/on 5,y
to turn on Plug 5, which powers up the TOFr Threshold System.
- Enter /S to check action completed, then
/x to exit the communication w/ the NPS unit.
- Note the action in the Shift Log Book.
THRESHOLD SYSTEM OFF
- Enter
/off 5,y
to turn off Plug 5, which powers down the TOFr Threshold System.
- Enter /S to check action completed, then
/x to exit the communication w/ the NPS unit.
- Note the action in the Shift Log Book.
|
|
Testing:
|
Completion:
- Contact TOFp Control to inform that
procedure is complete, and with any end-of-procedure comments that are necessary.
Was this procedure successful? Is this documenation understandable and complete?
|
|