Calibration in energy

Calibration

file = /star/data03/daq/2005/049/st_physics_6049030_raw_1020001.daq
cuProductionMinBias
- Here is a link to my previous study for the calibration : files from where I took the calibration values, and the first attempts are shown

For all Ladders


ladder 1 without calibration ladder 1 with calibration : 16/16 calibration values
ladder 2 without calibration ladder 2 with calibration no calibration
ladder 3 without calibration ladder 3 with calibration 13/16 calibration values
ladder 4 without calibration ladder 4 with calibration 15/16 calibration values
ladder 5 without calibration ladder 5 with calibration 15/16 calibration values
ladder 6 without calibration ladder 6 with calibration 16/16 calibration values
ladder 7 without calibration ladder 7 with calibration no calibration
ladder 8 without calibration ladder 8 with calibration no calibration
ladder 9 without calibration ladder 9 with calibration 15/16 calibration values
ladder 10 without calibration ladder 10 with calibration 12/16 calibration values
ladder 11 without calibration ladder 11 with calibration 15/16 calibration values
ladder 12 without calibration ladder 12 with calibration 16/16 calibration values
ladder 13 without calibration ladder 13 with calibration 14/16 calibration values
ladder 14 without calibration ladder 14 with calibration 16/16 calibration values
ladder 15 without calibration ladder 15 with calibration 14/16 calibration values
ladder 16 without calibration ladder 16 with calibration 9/16 calibration values
ladder 17 without calibration ladder 17 with calibration 16/16 calibration values
ladder 18 without calibration ladder 18 with calibration 15/16 calibration values
ladder 19 without calibration ladder 19 with calibration 11/16 calibration values
ladder 20 without calibration ladder 20 with calibration 14/16 calibration values
I indicate in blue the number of calibration values we have for each ladders, as there is 16 wafers per ladders. It may explain the difference in the efficiency in the calibration
For exemple, ladder 3 has 3 wafers which don't have calibrations values and ladder 4 has only 1 : the difference in the efficiency between these two ladders : But even we don't reach a deviation equal to 0 for the ladder 3, the calibration is quite efficient because we correct this ladder by almost 7 ADC.
There are still point to improve and investigate :

Results for 1 wafer especially

The black lign shows the perfect matching between the two sides : one can see that the calibration, for one wafer particularly, seems to be efficient.
Picture 1 : without calibration
Picture 2 : with calibration

Consequences of the Calibration

When the geometrical overlap of the clusters leads to ambiguous hits, the charge matching (same quantities of charges is collected on bothsides of the wafer) is used : (- Star note 0427 : Silicon Strip Detector Reconstruction Chain for the STAR Experiment.
Ambiguities arise for the package 2-2B so with the calibration, we hope to better reconstruct those cases .
Case1-1(1-2)A(1-2)AS(1-3)A(1-3)AS(2-2)A(2-2)AP(2-2)B(2-3)A(2-3)AP(3-3)A
Case012345678910total
Number of hits without the calibration7607533923040162049274678030521331592122492344
Number of hits with the calibration7603534023024164148674878230801295624123092347
Diff-40+10-16+21-6+2+2+28-36+32+6+3
Jonathan Bouchet