Requirement:
The maximum signal swing expected is 1500 mV,
due to an input Gaussian(=25 ns) dq/dt having total charge=360,000 e.
The expected signal swing expected with a 1 MIP step charge is 165 mV.
The maximum (not to exceed) output range is -.8 to 3.5 V.
Justification:
The device has to have a linear response in the range of minimum and maximum ionization.