Requirement:
Provide the signal and power interface between the readout boards (RDO's) and the Hybrids located at each end of a carrier.
Justification:
The approximately 3 m separation between the Hybrids and readout boards necessitates the buffering of signals. Space constraints at the Hybrid and overall design simplification suggests a dedicated module to perform such functions.