From: W.J. Llope (llope_at_hbar.rice.edu)
Date: Tue Jan 21 2003 - 19:26:13 EST


On Tue, 21 Jan 2003 JMEngelage_at_lbl.gov wrote:

> bill ---
> why am i not surprised.

LOL...

> i can reboot the system (ctb) whenever
> there is not beam.

that might be all we need...

> conversely, we can also load the channels you
> need using the gui.

if i understand you, this i know - it's what the shift crew
has been doing - or do you mean one can load *default* values
via the gui? (that'd be a feature i wasn't aware of....)
it's the default values that we're interested in setting
(right now semi-permanently) -> i.e. the ones that the gui automatically
brings all 6 voltages to when the crew clicks only the "pvpd on" from the
main panel (like last run)....

>what would you like me to do? the trigger
> cell is 631.786.0493 (if that doesn't work try my office 5371).

i'll try to ring you up tomorrow during the day (since i have a related
but somewhat less-critical question too)... but if you can reboot
the crate whenever after that we could ask the shift crew to do a test
power-up of the pvpd hv using solely the 'on' button to see if jumps to the
default set... that's all we're looking for - thanks again!
bill

>
> -j.
>
>
> ----- Original Message -----
> From: "W.J. Llope" <llope_at_physics.rice.edu>
> Date: Tuesday, January 21, 2003 12:02 pm
> Subject: CTB/pVPD HV.....
>
> > hi jack - in between the last run and this one, someone
> > edited the CTB HV definitions map in such a way that the
> > pVPD HV settings have disappeared.... (sigh)...
> > a few days ago tom mcshane added our values: here's a msg
> > from geary summarizing that:
> >
> > >What Tom did was edit a file demand.20030118 and add the pvpd hv
> > values>which were zero in this file. Whoever updated the ctb
> > voltages for this
> > >year must have edited an old file without the pvpd values. The
> > ctb values
> > >are in the same file. I don't think the new demand file will be
> > >effective until the trigger crate which controls the hv is
> > rebooted. I'll
> > >ask Jack to reboot during the shutdown Wednesday.
> >
> > so - we're thinking all that's needed is reboot of some trigger
> > crate...... is this somethign you can do? or who should i bug here?
> >
> > some more details are below in case you need them....
> >
> > thansk!
> > bill
> >
> > On Sun, 19 Jan 2003, W.J. Llope wrote:
> > >
> > > hi slow controls folks...
> > >
> > > TOF has a simple problem and we need your help a.s.a.p...
> > > BTW i tried and tried but couldn't find an email address for
> > > "Bill Wendt" (sp?) whom i'm told might be the guy to help me
> > here...> could any one of you guys forward this message to him too?
> > >
> > > last run dennis had set up the CTB HV GUI etc so
> > > that there were default pVPD HV values defined. in this case
> > > the shift crew just clicked pVPD ON or pVPD OFF and
> > > life was good.
> > > these settings have apparently disappeared since the
> > > last run, and our six default pVPD voltages are all zero now.
> > > this means some extra hassles for the shift crew, as they
> > > have to manually 'slide-up' our voltages each time they're
> > > powering up STAR after a new spill... the additional
> > > problem is that, to save time, right now i've just asked them
> > > to put all these at 2kV, which aren't really the values
> > > we want....
> > >
> > > so, can someone there revive the definitions of
> > > pVPD default HV values in the SC gui(s) the shift uses?
> > >
> > > the values we want are:
> > >
> > > pVPD ch. 1440 sl/ch # HV value (V)
> > > -------- ------------ ------------
> > > 1 (3/15) 1800
> > > 2 (4/15) 1927
> > > 3 (5/15) 2011
> > > 4 (6/15) 1764
> > > 5 (7/15) 2296
> > > 6 (8/15) 1886
> > >
> > > note the 1440 cr/sl values are unchanged since
> > > last run....
> > > thanks in advance! take care,
> > > bill
> > >
> > > p.s. i have a few add'l questions, but they can wait
> > > until this particular problem is fixed...... thanks again
> > >
> > >
> >
> > --
> >
> > W.J. Llope, Ph.D.                      Res. Assoc. Professor
> > T.W. Bonner Nuclear Laboratory         phone: 713-348-4741
> > Rice University, MS-315                fax: 713-348-5215
> > 6100 S. Main St.                  
> > Houston, TX 77005-1892            
> > e-mail: llope_at_physics.rice.edu
> > WWW home:   http://wjllope.rice.edu/default.html
> >
> > --
> >                       
> >
>
>

-- 
_________________________________________________________
W.J. Llope, Ph.D.                  Res. Assoc. Professor
                 http://wjllope.rice.edu/default.html
                 llope_at_physics.rice.edu
T.W. Bonner Nuclear Lab.     
Rice University, MS-315      
6100 S. Main                       phone: 713-348-4741  
Houston, TX 77005-1892             fax:   713-348-5215

Date view Thread view Subject view Author view Attachment view

This archive was generated by hypermail 2.1.4 : Thu Jul 24 2003 - 00:39:32 EDT