[Fwd: Re: power supply problems for Crate 63?]

Date view Thread view Subject view Author view Attachment view

From: Frank Geurts (geurts_at_rice.edu)
Date: Wed Feb 19 2003 - 13:30:13 EST


  we have a problem w/ the ps for crate 63. I've already asked Zhangbu
to check this.

-------- Original Message --------
Subject: Re: power supply problems for Crate 63?
Date: Wed, 19 Feb 2003 13:19:48 -0500 (EST)
From: Betty Bezverkhny <bbezverk_at_star.physics.yale.edu>
To: Frank Geurts <geurts_at_rice.edu>
CC: 'Xu, Zhangbu' <xzb_at_bnl.gov>

I was wrong, it's the +12V power supply.
When I turn the crate on, the current goes off scale.
Since we're not taking any data now, I turned the crate off altogether.
The problem started before access. As far as I can ascertain, no one has
been working on that crate before or since.

-Betty

------------------------------------------------------------------------------
Betty Bezverkhny

Yale University Physics Department
Wright Nuclear Structure Laboratory,
272 Whitney Avenue, Room 302
New Haven, CT 06511

203.432.9742
------------------------------------------------------------------------------

On Wed, 19 Feb 2003, Frank Geurts wrote:

> hi Zhangbu -- while you're on the platform, could you check on the ps of
> crate 63 (pVPD and other trigger-related HVs). Betty (who's on shift
> right now) saw what appears to be some problems in the +5V supply.
>
> TTYL,
> frank
>
>


Date view Thread view Subject view Author view Attachment view

This archive was generated by hypermail 2.1.4 : Thu Jul 24 2003 - 00:39:35 EDT