TOF TCD connections

Date view Thread view Subject view Author view Attachment view

From: John Mitchell (John.W.Mitchell_at_nasa.gov)
Date: Fri Feb 28 2003 - 13:56:13 EST


Hello Folks,
Sorry about weighing in late.

I have checked my original notes on the TCD as well as my logic
diagram. The TCD connections used by TOF are:

Out 2 - L0
Out 4 - Command 4 (used as pulser)
Det Live - TOF System Live (active high TTL when Live)

Frank had them correct in his earlier note. We also have Out 1
configured with a delayed RHIC strobe and Out 3 with Abort, but we
are not using these connections at present.

John

At 12:27 PM -0600 2/28/03, Frank Geurts wrote:
>Jack -- as far as I can tell these *should* be the TCD connections for TOF:
>* TOFp-L0 at TCD-Out 2
>* TOFp-Pulser at TCD-Out 4
>* TOF-System-Live at TCD Det Live (that's is easy because that one
>has a proper label at the TCD).
>


Date view Thread view Subject view Author view Attachment view

This archive was generated by hypermail 2.1.4 : Thu Jul 24 2003 - 00:39:36 EDT