Re: many, many TOFr trips

Date view Thread view Subject view Author view Attachment view

From: Frank Geurts (geurts_at_rice.edu)
Date: Tue Mar 25 2003 - 12:25:50 EST


Geary Eppley wrote:
> Hi Frank,
>
> Too late. I just swapped HVA+ with HVB+. If this is a temperature and
> humidity problem, it should follow the supply unless the current is
> developing in the HV cable connectors. If the tripping goes away
> altogether now, we can swap the cables back.

ok

>
> We ran under high temperature and humidity conditions at the AGS with only
> a few trips.

but that was a different PS ...