Re: hv etc

Date view Thread view Subject view Author view Attachment view

From: Frank Geurts (geurts_at_rice.edu)
Date: Wed Mar 26 2003 - 10:47:04 EST


W.J. Llope wrote:
>
> frank - where's the tofrhv.log data from before Tue Mar 25 14:53:00 2003?

/data/hv/tofr/eventlog/tofrhv030325.log

[...]

>
> another qquestion: i remember hearing that specific ramp
> parameters are set differently for busses A and B. (different
> trip limits too?). anyway, now that the cabling is swapped
> for the present test, do we not need to set those parameters
> as before to be consistent w/ the previous conditions?
>

trip limits are the same for all busses. The ramp parameters are still
set for the original configuration. Geary and I watched the new config
ramp up with these old parameters ... just to see how the A+ bus could
dealed w/ a higher ramp voltage. No problem at all so I am about to
change the ramping parameters for all channels accordingly limiting the
"dead" time of system after a trip (which was ~(3+7)min)


Date view Thread view Subject view Author view Attachment view