From: Frank Geurts (geurts_at_rice.edu)
Date: Thu Mar 27 2003 - 14:24:21 EST
dear tof experts -- hvmon has now an emulation mode which should be run
when the HVSys unit is physically disconnected. This mode reads the
current hvmap and assumes all set/read voltages are 0.
Make sure you run "hvmon status" to check whether the emulator is
running and do a "hvmon stop" to kill it after you switched to normal
operations (that is, when HVSys supply is back on). Use "hvmon start" to
continue its normal monitoring mode.
-frank
examples of emulation:
[tofp_at_tofpdaq hv]% hvmon
Usage: hvmon <start|emul|status|stop>
[tofp_at_tofpdaq hv]% hvmon emul
Warning: only use this when HVsys is physically switched off
[tofp_at_tofpdaq hv]% hvmon status
tofhv-Monitor is not running
tofhv-NoMonitor (pid 21211) is running...
emul: Thu Mar 27 12:59:08 2003
emul: Thu Mar 27 13:09:07 2003
emul: Thu Mar 27 13:19:06 2003
emul: Thu Mar 27 13:29:05 2003
emul: Thu Mar 27 13:39:05 2003
emul: Thu Mar 27 13:49:04 2003
emul: Thu Mar 27 13:59:03 2003
emul: Thu Mar 27 14:09:02 2003
Frank Geurts wrote:
>
> Yigun,
> the red-alert in SC should have dissapeared now. The slowcontrols event
> files for TOFp are filled again (with 0s, since the actuall supply
> remains to be shutdown)
>
> cheers,
> frank
>
>
>
>
>
> Yiqun Wang wrote:
>
>> Got it! We have been keeping an eye on TOFr. Once in a while, one of
>> the Iread value gets out of range, the voltage automatically reramp
>> itself. I am told that is normal.
>>
>> Yiqun Wang
>>
>> On Thu, 27 Mar 2003, W.J. Llope wrote:
>>
>>
>>> TOFp HV is not on. in fact that's why the light is red.
>>> SC is trying to communicate with a unit that is physically
>>> powered off.
>>> just ignore this red box until further notice...
>>>
>>> SC alerts for TOFr HV and/or Gas flow should *not* be ignored...
>>>
>>> thanks for the message,
>>> bill
>>>
>>>
>>>
>>> At 10:05 AM -0600 3/27/03, Yiqun Wang wrote:
>>>
>>>> Hi,
>>>>
>>>> I am the detector operator for shift 7:30-4:30PM. I see that there
>>>> is red
>>>> error on SC for tofp HV. Opening the corresponding window shows 4
>>>> channals
>>>> with HV values that are far out of normal set value range.
>>>>
>>>> We just ramped up the STAR magnet. There are some beams in the ring.
>>>> FEEs
>>>> for all other detectors are off. Jamie Donlup, the shift leader,
>>>> wonders
>>>> why the topf HV is on.
>>>>
>>>> Yiqun Wang
>>>>
>>>> --
>>>> -------------------------------------------------------------------------
>>>>
>>>> | Brookhaven National Lab Yiqun Wang |
>>>> | Building 902C, Room M6 Department of Physics |
>>>> | Upton, NY 11973-5000 University of Texas at Austin |
>>>> | Home: (631)395-5474 Austin, TX 78712 |
>>>> | Office: (631)344-5268 yqwang_at_physics.utexas.edu |
>>>> | (631)344-5746 |
>>>> -------------------------------------------------------------------------
>>>>
>>>
>>>
>>>
>>>
>>
>