From: Frank Geurts (geurts_at_rice.edu)
Date: Sat Apr 05 2003 - 12:14:32 EST
Geary Eppley wrote:
> Hi,
>
> After we swapped HVA+ back to the first output on Wednesday, there were no
> trips until 18:47 yesterday. Now it has started tripping a lot like it did
> in the last week of the dAu run. On next Wednesday's access, we should
> move HVA+ to the the 3rd output of the CAEN and see if that works. I guess
> this requires modification to the software as well.
yep, and probably SC needs a heads up too (since they still assume the
original 0:HVA+, 1:HVB+ setting)
-f.
This archive was generated by hypermail 2.1.4 : Thu Jul 24 2003 - 00:39:39 EDT