During 'normal' beam conditions the Iread values typically are 0 (which
means we have currents below 10nA). We can see higher values (up to
several hundereds of nA) during beam ramps or dumps. After a HV trip
you'll also see HV-ramping currents of ~450nA.

No problems, and the HV has been on all the time.

cheers,
frank