From: W.J. Llope (llope_at_physics.rice.edu)
Date: Mon May 26 2003 - 12:54:33 EDT
On Mon, 26 May 2003, Geary Eppley wrote:
> Hi,
>
> The tof racks (as well as much of STAR) was powered down by the global
> interlock system this morning, most likely a malfunction of the system.
> For example, we had high level fire and smoke alarms yet the alarm was not
> relayed to the fire department.
>
> In any event, is there anything I should worry about when the interlock is
> finally cleared and power is restored to the TOF racks? Will the systems
> come back up by themselves far enough that we can control things from
> tofpdaq?
hi -
thanks for the message....
after power is restored, the tofp systems all come up in a safe state.
i.e. the daq computer reboots into the mini-system, and all
nps plugs (except for the plug for this PC) will come up in the off state.
see:
http://mac8.rice.edu/~TOF/TOFp/operations/tofp_shiftcrewFYI.html
there is a recovery procedure linked there.
these steps should restore the systems needed to interact w/ star
and take data.
some things like the cron job that polls the caen for the 1/minute
tofr hv monitoring may or may not revive automatically so these
things have to be checked once the rest of the systems are up again...
let me know if you want me to just power it all up from here....
bill
> Geary
>
>
-- _________________________________________________________ W.J. Llope, Ph.D. Res. Assoc. Professor http://wjllope.rice.edu/default.html llope_at_physics.rice.edu T.W. Bonner Nuclear Lab. Rice University, MS-315 6100 S. Main phone: 713-348-4741 Houston, TX 77005-1892 fax: 713-348-5215