D0
Cut Variables Resolution in micro-Vertex code(MuKpi.C)
How?
Ø The
Good daughter tracks are found from the matchedpair info in .minimc.root file.
Ø The
same daughter tracks are found and D0 is reconstructed in MuKpi.C
Ø Do
the same in .geant.root file
Ø Plot
the difference.
1. Mass
Resolution
Reco Gauss Fit Reco Geant
Since the D0 mass is a single value in geant the
Reco distribution is the resolution. After doing a gauss fit to the peak the
resolution is ~0.8% (as expected)
1. Decay
Length distribution
Reco Geant
2. Distribution
of Eta of D0
3. Pz
Distribution of D0
4. Phi
Distribution
5. pT
Distribution of D0
6.
Resolution
of pT
mean(pTRECO
- pTGEANT)
A slope of 3MeV is
expected due to the decreasing D0 mass with pT increase. Here the slope is
2.17+-0.1MeV, which is in agreement with the above.
σ(pTRECO
- pTGEANT/pTGEANT)
For Sigma single Track
resolution is not expected.
Decay
Length Resolution pure D0 Sample:
mean(dLRECO
- dLGEANT)
σ(dLRECO - dLGEANT/dLGEANT)