Requirement:
The position resolution is supposed to be 25
m
25
m.
The
electronics should contribute no more than 10% to this resolution.
Justification:
Primary vertex, secondary vertex, momentum and two track
resolution depend on the position resolution. Above 25 m
25
m the
track efficiency also starts to degrade.
Status:
included as system specification