next up previous
Next: Redundancy Up: Hybrid Previous: Signal to Noise

Position Resolution

Requirement:

The position resolution is supposed to be 25 m 25 m. The electronics should contribute no more than 10% to this resolution.

Justification:

Primary vertex, secondary vertex, momentum and two track resolution depend on the position resolution. Above 25 m 25 m the track efficiency also starts to degrade.

Status:

included as system specification



Claude Andre Pruneau