TOF SC interface

Date view Thread view Subject view Author view Attachment view

From: Frank Geurts (geurts_at_rice.edu)
Date: Tue Feb 25 2003 - 13:03:23 EST


Hi Steve,
  I just looked at the monitoring GUIs for TOF, looks great! Just a few
quick comments:
* the HV branches show up with really weird numbers, almost like
something went wrong in reading floating points put printing them like
integers ...
* I am slightly puzzled by the hvcell=vread=vset=0 for TOFp cell 39
* Also, the HVset for all HVcells is always 0 ... but the HVsets in the
4th column is not

* could you count the TOFp#s for the TOFpHV from 1 to 41 (instead of 0
to 40) ...in that way they are consistent w/ the tofphv.map and with the
online documentation of the HVSys.

* Bill L. requested the phrase "High Voltage Branch X" to be changed
into "Voltage Branch X", since its only ~200V.

* I would like to run these displays on the TOFp box in the STAR control
room and make it easy for other TOF folks do so too. Could you provide
an easy alias (like tof_top) which allows the three windows to pop up --
or even better, have one TOF window from which the user can click on
tofphv, tofrhv or tofrgas ... or am i now really pushing my luck here ;)

thanks!!
  -frank


Date view Thread view Subject view Author view Attachment view

This archive was generated by hypermail 2.1.4 : Thu Jul 24 2003 - 00:39:36 EDT