Re: tof status?

Date view Thread view Subject view Author view Attachment view

From: Frank Geurts (geurts_at_rice.edu)
Date: Sun Mar 16 2003 - 03:30:09 EST


I suppose we are still waiting for an access in order to check the rear
connector of the TOF TCD (Eleanor?). I would like to suggest STAR asking
for an emergency access (~15min max) to fix this ... we have already
lost two days of data and TOFp is considered to be a base line
detector, right?

W.J. Llope wrote:
> hi guys,
> last i heard we believed the present problem w/ tof (i.e. ,runs fine
> for only first ~5k events than hangs DAQ) in run control was related to
> our TCD (see msg from frank) or beyond, and eleanor was going to contact
> freddy... did this happen? or someone know the latest status
> on this? thanks
> bill
>

Fred send out this email (cc'd to tofp_at_physics.rice.edu) Friday at 4h53pm:
> fred bieser wrote:
>
>> Te TOF's TCD has NO internal logic to generate busy except as brought in
>> thru the front-panel LEMO labelled "DAQ Live." All the recent activity
>> in that area might have left some cable loose or dropped or ???? either
>> at the front or, more likely, in the rear.
>>
>> fred
>>

cheers,
- Frank


Date view Thread view Subject view Author view Attachment view

This archive was generated by hypermail 2.1.4 : Thu Jul 24 2003 - 00:39:37 EDT